How to Perform Hand-Eye Calibration
Hand-Eye Calibration Terms and Concepts
-
Hand-eye calibration
Calculates the transformation relationship between the robot coordinate system and the camera coordinate system by collecting the calibration target pose captured by the camera and the robot pose. The transformation matrix can convert target points from the camera coordinate system to the robot coordinate system, enabling robot operation guided by 3D vision. Hand-eye calibration accuracy is critical because it directly affects system accuracy and stability.
-
Camera installation method
Installation method
Description
Illustration
Eye-in-hand (EIH)
The camera is mounted on the robot end effector, remains fixed relative to the flange coordinate system, and moves with the robot end effector.

Eye-to-hand (ETH)
The camera is mounted in a fixed position, and its position relative to the robot base coordinate system remains unchanged.

-
Point-pair data
A pair of pose data for the same feature point in the camera and robot coordinate systems.
Hand-Eye Calibration Tutorials
Refer to the hand-eye calibration tutorial that matches your actual setup.
Scenario |
Tutorial |
|---|---|
Hand-eye calibration in an eye-to-hand (ETH) setup |
|
Hand-eye calibration in an eye-in-hand (EIH) setup |
|
When to Perform Hand-Eye Calibration Again
Perform hand-eye calibration again in any of the following situations:
-
The camera or robot is replaced.
-
In an eye-to-hand setup, the camera position changes relative to the robot base coordinate system.
-
In an eye-in-hand setup, the camera position changes relative to the robot flange coordinate system.