How to Adjust Parameters
This chapter introduces operations related to parameters, including the general workflow of adjusting parameters, and managing parameter groups.
General Workflow of Adjusting Parameters
Follow thses steps to adjust parameters:
-
Create a parameter group.
Click [+] to create a parameter group, which is used to record and save parameters that are only suitable for the current scenario.
-
Select a camera capture mode.
Epic Eye supports multiple imaging modes, including structured light, oscillating line scan, fixed line scan, three-channel video stream, and passive stereo imaging. Each mode is suitable for different application scenarios:
-
Video stream mode — Acquires only 2D images without performing 3D reconstruction
-
Structured light mode — Projects area structured light using the projection system for 3D reconstruction
-
Passive stereo mode — Performs 3D reconstruction using only stereo vision, without projection
-
Oscillating line scan mode — Performs 3D reconstruction by projecting and scanning a single laser line
The supported imaging modes vary by camera model. Select an appropriate imaging mode for parameter adjustment based on the camera model in use.
-
-
Acquire data.
Acquire data as a reference for parameter adjustment.
Click Capture in the lower right corner of the software interface to acquire data.
-
Check the data quality.
After acquiring data, please make sure that the 2D image, depth map and point cloud are meet the requirements.
-
2D image: The surface features of the target object should be clearly visible.



Too dark
Good
Too bright
-
Depth map and point cloud: target object data should be complete.


Incomplete
Complete
-
-
Adjust parameters.
If the data quality is poor, you must adjust the corresponding parameters in the Parameter tab on the right。
Parameter adjustment procedures vary by model. Refer to Non-Laser Camera Parameters, Laser Camera Parameters, or V3 Series Camera Parameters.
-
Check the data quality after parameter adjustment.
After adjusting the parameters, you need to acquire data to check whether the data quality meets the requirements. Click Capture in the lower right corner of the software interface to acquire data, then check the data quality.
-
Repeat adjustment.
Repeat the above steps until the data quality meets the requirements.
You can adjust 2D parameters (open or close LED for laser camera) and view the data in the operations-capture.adoc#operations-capture-real-time, to find appropriate parameters.
Manage Parameter Group
A parameter group is used to store parameter values applicable to different scenarios, workpieces, and solutions. When the scenario or workpiece changes, simply switch the parameter group to quickly apply the corresponding parameter values
Descriptions about parameter group are as follows:
Switch Parameter Group(1)
-
Click ˅ next to the parameter group name to expand the drop-down menu.
-
Select any parameter group from the drop-down menu.
Create a New Parameter Group(2)
-
Click btn[+].
-
In the pop-up window, enter the name of the parameter group and click OK.
-
The newly created parameter group will be added to the parameter group drop-down menu.
Rename Parameter Group(4)
-
Click
. -
In the popup window, enter the new parameter group name.
-
Click OK, and the parameter group name will be updated.
Export Parameter Group(5)
-
Click ….
-
Click Export data, choose the save path, and the software will export the data of all parameter groups into a file.
Import Parameter Group(5)
-
Click ….
-
Click Import Data, select the parameter group file to import, and the software will automatically load the parameter values.