Eye-to-Hand — Three-Axis Robot

Preparation

  • Connect the camera, industrial PC, and robot hardware systems.

  • Place the calibration board at the center of an area within the robot’s range of motion, and ensure that its position remains unchanged throughout calibration.

  • Start the intrinsic parameter inspection tool in Epic Eye to check the camera intrinsic parameter accuracy.

  • Capture one image with Epic Eye. Ensure that the calibration board is clear and moderately exposed in the 2D view, and that its point cloud is flat in the point cloud view.

Calibration Procedure

1. Enter the Calibration Procedure

After entering the hand-eye calibration tool, select the eye-to-hand camera installation method in the right-side parameter panel.

2. Select a Robot

Select the robot used for calibration and click Next to open the robot absolute positioning accuracy inspection interface.

3. Inspect Robot Absolute Positioning Accuracy

Complete the inspection in at least one of the X, Y, and Z directions. For more reliable results, completing the inspection in all three directions is recommended.

  • (1)Select one of the X, Y, or Z directions under Inspection Type.

  • (2)Click Start Data, then Get Pose to update the calibration board pose in the start data. Manually enter the robot pose shown on the robot teach pendant.

  • (3)Click End Data, move the robot a distance in the selected direction, and click Get Pose to obtain the calibration board pose in the end data. Manually enter the robot pose shown on the teach pendant.

  • (4)Click Calculate Accuracy to view the inspection result. Determine whether the result meets the requirements according to the actual project requirements.

After inspecting at least one direction, click Next to open the point-pair data list.

4. Acquire Point-Pair Data

Use the teach pendant to move the robot, ensure that the calibration board is centered in the camera field of view, and click Acquire Point-Pair Data in the point-pair list. The current calibration board pose, robot pose, and measurement accuracy are obtained.

A measurement accuracy from 0.997 to 1.003 is shown in green and is usable. A value from 0.993 to 0.997 or from 1.003 to 1.007 is shown in yellow and indicates risk. A value below 0.993 or above 1.007 is shown in red and is unusable; delete the data and acquire it again.

5. Adjust the Calibration Board Pose

calibration board pose 3

After acquiring the first point-pair data, adjust the calibration board pose while keeping it within the camera field of view, so that its pose changes between acquisitions.

6. Acquire Point-Pair Data Again

After adjusting the calibration board pose, click Add to acquire the second point-pair data. Repeat the adjustment and acquisition steps above until at least 10 sets of point-pair data have been acquired.

7. Calculate Point-Pair Data

Click Calculate Hand-Eye Calibration Result to calculate all acquired point-pair data and obtain the hand-eye calibration result.

It is recommended to perform a calculation after acquiring four sets of point-pair data, and after each additional set thereafter.

8. View the Hand-Eye Calibration Result

Click View Calibration Result to open the calculation result window and view the hand-eye calibration result.

9. Additional Data for a Three-Axis Robot

For a gantry robot, confirm that the gantry robot coordinate system is right-handed.
  • (1)Confirm that the hand-eye calibration result error from the previous step meets the requirements.

  • (2)Move the robot so that the calibration board is centered in the camera field of view.

  • (3)Click Hand-Eye Calibration Accuracy Check, enter the current robot pose data into Robot Pose, and click Get Pose and Send to Robot to record the calibration board pose in the robot coordinate system.

  • (4)Move the robot end effector to the calibration board origin and record the robot end-effector pose shown on the teach pendant.

The calibration board origin is updated to the position indicated by the arrow in the figure below.

calibration base point
  • (5)Subtract the calibration board pose in the robot coordinate system from the robot end-effector pose to obtain the X, Y, and Z offsets, and enter these values under Three-Axis Additional Data.

10. Recalculate the Point-Pair Data

Click Calculate Hand-Eye Calibration Result to calculate the hand-eye calibration result again.

11. View the Calculation Result

Click View Calibration Result to open the calculation result window and view the hand-eye calibration result. Judge whether the result is usable from the difference between the average translation error and maximum translation error. An error below 1 mm indicates that the result can be used.

12. Hand-Eye Calibration Accuracy Check

  • (1)Click Next to open the hand-eye calibration accuracy inspection interface.

  • (2)Select the Z-axis orientation and click Get Pose. The obtained pose is the calibration board origin pose.

  • (3)Try to move the robot to this pose and check whether it can reach the calibration board origin. If it can, the hand-eye calibration accuracy meets the requirements. If it cannot, perform the accuracy inspection again.