Epic Eye Laser M V3

Safety Instructions

Safety Statement

  • Before using this product, please read the product manual and fully understand the relevant safety information. Failure to follow the instructions may result in equipment damage, serious injury, or death.

  • Transfer assumes no legal responsibility for any personal injury, property loss, or other accidents caused by non-compliance with this manual or improper operation of the product.

Precautions

  • Avoid using the camera in environments with dust, strong electromagnetic interference, direct sunlight, or outside the specified temperature and humidity range.

  • Do not stare directly into the projection beam while the camera is operating to avoid eye injury.

  • Ensure the camera window is clean. Use a lint-free cloth to clean the window if necessary.

  • Do not perform installation, disassembly, or cleaning while the camera is powered on.

  • During transportation and installation, avoid severe impact or dropping of the camera.

  • If any abnormal conditions occur (e.g., unusual sounds, odors, or smoke), immediately cut off the power and perform an inspection.

  • Do not modify the camera or its power cables.

Packing List

hardware V3 unbox

Upon unboxing, check the camera and its accessories for any damage, rust, or deformation, and verify the completeness of the items against the packing list. If any damage or discrepancies are found, please contact Transfer.

Technical Specifications

Technical Parameters

System Parameters

Baseline Length

110mm

Recommended Working Distance

500mm~1500mm

Optimal Working Distance

900mm

Near Field of View

625mm×650mm@0.5m

Far Field of View

1730mm×1840mm@1.5m

Z-Axis Accuracy

0.04mm@0.7m

Pixel Count

2 million, 8 million

VDI/VDE Measurement Accuracy

0.06@1.5m

Resolution

Depth Map: 2840×2840, 1420×1420

RGB: 8000×6000, 4000×3000, 2000×1500

Accuracy Error

<0.15%

Typical Acquisition Time

0.3s~0.9s

Power Supply(1)

24V ⎓ 5A

Peak Power

30W

Average Power Consumption

16W

Standby Power Consumption

6.7W

Hardware Parameters

Dimensions (L*W*H)

155mm×80mm×66mm

Installation Method

Fixed Installation / End-Effector Installation

Communication Interface

Gigabit Ethernet

Light Source

Blue (450nm) laser

2D Camera

Color

Smart Camera Parameters(2)

Memory

16G

Storage

128G

Computing Unit

CPU, GPU, NPU

Environmental Parameters

Operating Temperature Range

-10℃~45℃

Operating Humidity

20%~90% RH (non-condensing)

Protection Level

IP65/IP67

Cooling Method

Passive

Weight

0.95kg

Storage Temperature

-20℃~70℃

Storage Humidity

20%~90% RH (non-condensing)

(1): This power supply specification is the factory standard. If selecting a power supply independently, the rated voltage must be ≥24V and the rated current ≥2.5A.

(2): This parameter applies only to Smart Camera products.

If the parameter content in this manual is updated, no separate notice will be provided. Please refer to the latest published data for accuracy.

Dimensions

Unit: mm

hardware V3 dimensions

Laser Product Safety

Laser Parameters

Wavelength

450nm

Laser Class

Class 3R

Laser classification is performed in accordance with IEC 60825-1:2014.

Label

laser tag V3

Label Placement Position

laser tag position V3

Ports and Indicators

hardware V3 port

The indicator light colors and their corresponding states are shown in the table below:

Color

Status

Blue light flashing

Camera initialization

Blue light on

Normal operation

Red light on

Hardware failure

Yellow light on

Network failure

Installation and Connection

Installing the Camera

Installation Method 1:

hardware V3 mount instructions

Installation Method 2:

hardware V3 mount instructions 1
  • Avoid single-handed operation. It is recommended to use a support to prevent the camera from falling or being damaged.

  • Tighten screws diagonally and progressively to avoid tilting or uneven stress on the camera.

Mounting the Camera on the Bracket

hardware V3 mount instructions 2
  • It is recommended to install the camera directly above the center of the pallet (bin), with no obstructions within the camera’s field of view.

  • It is recommended that the bottom surface of the camera be parallel to the plane of the pallet (bin).

  • The screws required for mounting the bracket are to be selected by the user according to the bracket specifications and installation requirements; they are not included in the packing list.

Connecting Cables

Connection Notes

  • Do not connect or disconnect cables while powered. Ensure all cable connections are complete before turning on the power.

  • Align the plug and socket, then tighten slowly. Do not force the connection.

  • It is recommended to use cable ties to secure the camera network cable, power adapter, and power cable.

  • When using a router, insert all network cables into the LAN ports of the router.

  • When using a router or switch, it is recommended to use a Gigabit router, Gigabit switch, and Gigabit dual-head RJ45 cables.

Connection Methods

  • Direct connection between camera and IPC

    hardware V3 connect direct
    1. IPC; 2. Camera network cable; 3. Camera; 4. M12-4Pin-5m DC power cable; 5. DIN rail power supply; 6. Robot

  • Connection between camera and IPC via switch

    hardware V3 connect router
    1. IPC; 2. Network cable; 3. Switch; 4. Camera network cable; 5. Camera; 6. M12-4Pin-5m DC power cable; 7. DIN rail power supply; 8. Robot

Smart Camera Cable Connections

Connection Notes

  • During debugging, prepare a display device on the same network as the camera, such as an IPC or laptop.

  • After debugging is complete, the display device can be disconnected and operation can continue.

Circuit Connection

  • Direct connection between smart camera and robot

    hardware smart V3 connect direct
    1. Display device (connected during debugging); 2. Camera network cable; 3. Camera; 4. M12-4Pin-5m DC power cable; 5. DIN rail power supply; 6. Robot (connected during operation)

  • Connection between smart camera and robot via switch

    hardware smart V3 connect router
    1. Display device (connected during debugging); 2. Network cable; 3. Switch; 4. Camera network cable; 5. Camera; 6. M12-4Pin-5m DC power cable; 7. DIN rail power supply; 8. Robot

Power Cable Technical Specifications

Physical Parameters

Model

Straight

Angled

CBL-PWR-12-3M

CBL-PWR-12-5M

CBL-PWR-12-10M

CBL-PWR-12-15M

CBL-PWR-12-3M-LU

CBL-PWR-12-5M-LU

CBL-PWR-12-10M-LU

CBL-PWR-12-15M-LU

Color

Black

Outer Sheath Material

PA

Outer Diameter

6.2(+0.25/-0.25)mm

Connector

M12, straight or angled, 4-pin / flying leads

Conductor Diameter

4*20 AWG

Static Bending Radius

79 mm

Dynamic Bending Radius

90 mm

EMI Shielding Performance

Aluminum foil and metal braid, dual-layer shielding

Safety

Compliant with RoHS standard

Flame Resistance Rating: VW-1

Cable Carrier Test

Bending Radius: 79mm

Stroke: 1000mm

Speed: 2000 mm/s

Cycles: ≥ 10 million

Compatible Camera Model

Laser M V3

Dimensions

Unit: mm

hardware V3 dimension 1

Model

L

CBL-PWR-12-3M

3m

CBL-PWR-12-5M

5m

CBL-PWR-12-10M

10m

CBL-PWR-12-15M

15m

hardware V3 dimension 2

Model

L

CBL-PWR-12-3M-LU

3m

CBL-PWR-12-5M-LU

5m

CBL-PWR-12-10M-LU

10m

CBL-PWR-12-15M-LU

15m

Connector

hardware V3 dimension 3

Function

M12 Connector Pin

Flying Lead Wire Color

Reserved Control Line

1, 2, 3, 4

-

0V

5

Black

+24V

6

Red

+24V

7

Brown

0V

8

Blue

Conductors

hardware V3 dimension 4

Function

Wire No.

Wire Color

Terminal Color

0V

5

Black

Green

+24V

6

Red

Red

+24V

7

Brown

Red

0V

8

Blue

Green

Connection Instructions

Unit: mm

hardware V3 dimension 5

Network Cable Technical Specifications

Physical Parameters

Model

Straight

Angled

CBL-ETH-12-3M

CBL-ETH-12-5M

CBL-ETH-12-10M

CBL-ETH-12-15M

CBL-ETH-12-3M-LU

CBL-ETH-12-5M-LU

CBL-ETH-12-10M-LU

CBL-ETH-12-15M-LU

Color

Black

Outer Sheath Material

PA

Filling

Cotton thread

Outer Diameter

7.6(+0.25/-0.25)mm

Connector

M12, straight or angled, 4-pin

Conductor Diameter

4*2*26 AWG

Static Bending Radius

79 mm

Dynamic Bending Radius

90 mm

EMI Shielding Performance

Aluminum foil and metal braid, dual-layer shielding

Safety

Compliant with RoHS standard

Flame Resistance Rating: VW-1

Cable Carrier Test

Bending Radius: 79mm

Cycles: ≥ 10 million

Compatible Camera Model

Laser M V3, Laser L V2S, Log L

Dimensions

Unit: mm

hardware V3 net dimension 1

Model

L

CBL-ETH-12-3M

3m

CBL-ETH-12-5M

5m

CBL-ETH-12-10M

10m

CBL-ETH-12-15M

15m

hardware V3 net dimension 2

Model

L

CBL-ETH-12-3M-LU

3m

CBL-ETH-12-5M-LU

5m

CBL-ETH-12-10M-LU

10m

CBL-ETH-12-15M-LU

15m

Connector

hardware V3 net dimension 3

Function

M12 Connector Pin

M2+

1

M2-

2

M0+

3

M0-

4

M1+

5

M1-

6

M3+

7

M3-

8

Connection Instructions

Unit: mm

hardware V3 net dimension 4

Connecting the DIN Rail Power Supply

Connection Notes

  • Before connecting cables, use a Phillips screwdriver to loosen the terminal ports. Tighten the ports after connecting the cables.

  • Connect and secure all ports before turning on the power. Do not connect or disconnect cables while powered.

Input Connection

hardware pixel mini power 1

Output Connection

hardware V3 power 2

Calibration Board Installation

hardware pixel pro calibration
  • Ensure the calibration board surface is free of scratches and stains, and that the bracket structure is intact.

  • Confirm that the holes are aligned, then tighten the screws in sequence to avoid looseness or excessive tightening that may cause deformation.

  • After installation, gently shake the calibration board to ensure it is stable with no looseness or wobbling.

Maintenance

Regular maintenance is essential for ensuring the stable operation and measurement accuracy of industrial 3D camera hardware. It not only extends the service life of the equipment, but also helps detect and prevent potential issues in a timely manner, reduces equipment failure rates, and ensures continuous and stable production line operation. Please strictly follow the prescribed maintenance procedures and keep relevant records.

Daily Inspection

  • Check whether the power supply status is normal. Regularly inspect the power cable connectors for good contact, ensure the power supply voltage output is stable and meets the power supply specifications. If necessary, it is recommended to use a UPS uninterruptible power supply to prevent unexpected power outages.

  • Check whether the network connection is stable and ensure the network transmission speed meets requirements.

  • Monitor whether the working environment temperature and humidity comply with specifications. Good ventilation is recommended to ensure normal heat dissipation of the camera.

  • Check the integrity of the camera housing to ensure there is no breakage, deformation, or corrosion, and avoid risks of scratching or colliding with surrounding objects.

  • Check the tightness of the camera mounting and adapter components to ensure there is no deformation, looseness, or wobbling.

  • Check the stress on cable connectors to ensure cables are routed properly without excessive bending, and the outer sheath shows no aging or cracking.

Regular Cleaning

Regularly clean the camera to ensure the lens is clean and free of obvious dust and stains. Use a clean soft cloth to wipe the camera body. Use a clean, soft, lint-free cloth dampened with lens cleaner or glass cleaner to wipe the camera lens to avoid scratching it.

Precautions

  • The equipment must be powered off before maintenance to prevent laser radiation exposure.

  • Do not use alcohol or other corrosive cleaning agents.

Storage and Transportation

  • Store and transport the camera in its original packaging or a professional shock-proof case.

  • Ensure the storage environment temperature and humidity meet the standards.

  • Avoid severe vibration and impact, and keep away from strong magnetic fields.

  • Maintain the correct orientation and avoid direct exposure to sunlight or other strong light sources on the lens.

  • Before long-term storage, perform a thorough cleaning first and conduct regular power-on checks (every 3 months).

Fault Prevention and Repair

Fault Prevention

  • Establish an equipment maintenance record to document all maintenance operations and abnormal situations.

  • Regularly check the camera’s internal parameter data and recalibrate if necessary.

Equipment Repair

Do not disassemble or repair this equipment yourself to prevent laser radiation and equipment damage. If a malfunction occurs, contact Transfer technical support immediately for factory repair. Transfer assumes no responsibility for equipment damage or accuracy degradation caused by any unauthorized disassembly or repair; any resulting losses shall be borne by the user.

Technical Support Channel

For technical support, please call the official service hotline at 4000-191-161 and follow the voice prompts to press 3 to reach the technical support channel.

Certification Information

alt altalt alt

Disclaimer

Transfer assumes no legal responsibility for any personal injury, property loss, or other accidents caused by the user’s failure to comply with safety regulations, improper operation of the camera, or unauthorized modification of the camera or power cables.

© 2026, Beijing Transfer Technology

All content in this manual, including text and images, is owned by Beijing Transfer Technology. Reproduction, modification, translation, or distribution of all or part of this manual without authorization is strictly prohibited.

Trademark Statement

Transfer, company logo and other Transfer series trademarks and logos are registered trademarks of Beijing Transfer Technology or its affiliated entities and are protected by law.