Save Image and Point Cloud

Description

Save the input point cloud and image data in real-time. Supports custom save paths, automatic cleaning of expired files (based on memory limits), and an optional FTP data upload function.

Overview

Writes point clouds and images to PLY and PNG files.

Scenarios

  • When pairing each frame’s 3D point cloud with its corresponding color image during data collection, for subsequent annotation and algorithm validation

  • When simultaneously recording 3D and 2D data during debugging to quickly identify 3D-2D consistency issues

  • When batch saving multiple frames of point clouds and images for offline evaluation or visualization playback

Inputs and Outputs

Inputs

Image: Input image. Supports any image data type.

Point Cloud: Input point cloud. Supports any point cloud data type.

Enable Switch: Enables the node function. Default is True. If the input is False, no data will be saved.

Outputs

File Name: The base file name used for this save operation (without extension). Outputs null when the enable switch is False or both inputs are empty. Point cloud files use .ply suffix; image files use .png suffix.

Parameters

Initialization Parameters

Save to FTP

Description

Controls whether generated files are uploaded to an FTP server after the local write completes. When disabled, files remain local only; when enabled, this operator uses its FTP connection settings for upload.

Tuning Instructions

Turn it off for local files only; turn it on and configure all FTP connection settings when upload is required.

Parameter Range

Default: False

Delete Local Data

Description

Determines whether the local copy is retained, and applies only after a successful FTP upload. true removes the uploaded local file to reclaim space; false keeps both local and remote copies. A failed upload does not cause local deletion.

Tuning Instructions

Turn it on to reclaim local space, or off to retain a local copy after upload.

Parameter Range

Default: True

FTP IP Address

Description

Specifies the FTP server hostname or IP address. Enter the endpoint supplied for the deployment; do not expose the real address in documentation, logs, or screenshots.

Tuning Instructions

When FTP upload is enabled, enter the server hostname or IP address provided for the deployment.

Parameter Range

Default: 192.168.33.18

FTP Port

Description

Specifies the FTP control-service listening port. It must match the server configuration and network rules; this is a port number, not the passive-mode data-port range.

Tuning Instructions

When FTP upload is enabled, enter the configured control port and ensure that the network permits it.

Parameter Range

Default: 8089

FTP Username

Description

Specifies the FTP login username. Use a least-privilege account provisioned for the deployment; do not disclose the actual username in descriptions, logs, or screenshots.

Tuning Instructions

When FTP upload is enabled, enter an account with write access to the target directory.

Parameter Range

Default: admin

FTP Password

Description

Specifies the FTP login password. This is a sensitive credential: enter it through controlled configuration and never place it in documentation, logs, screenshots, or version control.

Tuning Instructions

When FTP upload is enabled, enter the selected account password and handle it as a sensitive credential.

Parameter Range

Default: qy123456

FTP Directory

Description

Specifies the destination directory on the FTP server. This is a remote path, not the local save path; the account must have create or write permission there.

Tuning Instructions

Select a remote directory writable by the account; it does not replace the local save path.

Parameter Range

Default: data

Run Parameters

Save Path

Description

Specifies the local output directory. When empty, the ATOM cache directory is used. FTP transfer still creates a local file first and then handles it according to the FTP settings.

Tuning Instructions

Select a writable directory when a specific location is required; leave it empty to use the ATOM cache directory.

Save Name

Description

Specifies the base output name without an extension. The operator adds the format-specific extension and, in multi-file mode, a timestamp or index.

Tuning Instructions

Enter a base name without an extension; the operator appends a timestamp when accumulating files.

Parameter Range

Default: data

Save Single File Only

Description

Selects overwrite or accumulation behavior. true uses a fixed base name and overwrites same-name output, retaining only the latest content; false adds a timestamp and creates new files on each execution.

Tuning Instructions

Turn it on to retain only the latest same-name result; turn it off to create a new timestamped file each time.

Parameter Range

Default: False

Max Storage Memory

Description

Limits the total space used by same-type output files in the save directory. When a write may exceed the limit, the oldest same-type files are removed first; this is not a per-file size limit.

Tuning Instructions

Set it to the total disk space available for same-type outputs; lower values remove old files sooner, while higher values retain more history.

Parameter Range

[0.00001, 4000.0], Default: 10.0, Unit: GB

Parameter Range

Values/Range: [1e-05, 4000.0]

Default: 10.0

Unit: GB

Save as Binary

Description

Selects PLY encoding. true writes binary PLY, typically smaller and faster to read or write; false writes human-readable ASCII PLY, usually with a larger file size.

Tuning Instructions

Turn it on for compact, faster PLY I/O; turn it off when human-readable PLY text is required.

Parameter Range

Default: True

Save Colored Point Cloud

Description

Interprets the last three channels of a six-channel point cloud. true writes them as color; false writes them as normals. Three-channel XYZ input is unaffected.

Tuning Instructions

For six-channel input, turn it on when the last three channels are color or off when they are normals; no adjustment is needed for XYZ input.

Parameter Range

Default: False