Save Detection Results
Description
This operator is used to save the detection results (JSON files) generated in the image detection process and the corresponding original images (multiple PNG images packaged as a ZIP file) to a specified local location. The data can be directly uploaded to annotation websites for use.
Overview
Packs and saves the detection result JSON file and the corresponding original image to a specified path in real-time.
Scenarios
Saving detection result data, which can be uploaded to annotation websites as raw data for subsequent manual fine-grained annotation or adjustment.
Inputs and Outputs
Inputs |
Detection Results: Includes bounding boxes, classes, scores, polygons, and other information. Image: Input image. Must be an RGB color image. Enable Switch: Enables the node function. Default is True. If the input is False, no data will be saved. |
Outputs |
Save Path: The absolute folder path where the data is successfully saved. |
Parameters
Initialization Parameters
Save to FTP
Description |
Main switch for background FTP upload functionality. |
Tuning Instructions |
|
Parameter Range |
Default: False |
Run Parameters
Save Path
Description |
Used to specify the target folder path for saving files. |
Tuning Instructions |
If no path is entered, the operator will by default save to the ATOM cache directory. |
Save Name
Description |
Specifies the name prefix of the saved file, without the file extension. |
Tuning Instructions |
It is recommended to use a descriptive name to facilitate subsequent retrieval and management. Default name: data |
Parameter Range |
Default: data |
Save Single File Only
Description |
Sets the file saving strategy: save as a single file or multiple files. |
Tuning Instructions |
|
Parameter Range |
Default: False |
Max Storage Memory
Description |
Sets the maximum total size of files allowed in the save directory. When the limit is exceeded, the software deletes the oldest files of the same type. |
Tuning Instructions |
Range: [0.00001, 10] GB, Default value: 10 GB. |
Parameter Range |
Values/Range: [1e-05, 4000.0] Default: 10.0 Unit: GB |
Enable Smoothing
Description |
Whether to smooth the edges of input detection results. Applied only to polygons with more than 4 points. |
Parameter Range |
Default: True |
Annotation Smoothing Granularity
Description |
Maximum distance between the original curve and its approximation. Points whose distance to the curve segment is less than this value are removed. Larger values yield fewer annotation points (coarser); smaller values yield more points (closer to original contour) but may affect subsequent annotation adjustment. |
Parameter Range |
Values/Range: [0.01, 50] Default: 1 |