Configure 3D ROI With Normals

Description

Configures and adjusts the 3D ROI. Users can configure the ROI position, size, and orientation by directly entering ROI data in the operator’s parameter panel or through visual dragging. When the operator runs, it will use the ROI finally configured in the parameters to crop the input point cloud.

Overview

Visually adjusts a 3D ROI and crops point clouds with normals.

Scenarios

Adjust ROI: Configure the ROI through input parameters or visual adjustment instead of upstream input, facilitating debugging or template configuration.

Inputs and Outputs

Inputs

Point Cloud: The input point cloud or list of point clouds to be cropped.

Outputs

Point cloud after ROI cropping: The list of point clouds cropped using the ROI configured in the parameters.

3D ROI: The ROI configured in the parameters.

Parameters

3D ROI

Description

One adjustable 3D ROI containing local minimum/maximum bounds and its pose; the node returns it and crops every cloud with it.

Tuning Instructions

Move, rotate, or resize the ROI to cover the spatial region to retain.

Parameter Range

Set according to the input data

Parameter Range

Default: [{"min": [0, 0, 0], "max": [0, 0, 0], "transform": [0, 0, 0, 0, 0, 0]}]

Keep Original Size

Description

For organized input, enabling preserves the original width and height and fills removed points with NaN; disabling crops the 2D structure to the smallest valid bounds.

Tuning Instructions

Enable when downstream pixel correspondence is required; disable for a smaller output region.

Parameter Range

Default: False

Enable Invert

Description

When disabled, outputs points inside the ROI; when enabled, outputs points outside it.

Tuning Instructions

Disable to retain the target region; enable to exclude it and retain the surrounding space.

Parameter Range

Values/Range:

  • True

  • False

Default: False

Merge Output Point Clouds

Description

After cropping multiple inputs, enabling concatenates them along width into one output; disabling keeps separate outputs.

Tuning Instructions

Enable for one downstream cloud; disable to preserve input-cloud boundaries.

Parameter Range

Values/Range:

  • True

  • False

Default: False