Cluster Filter With Normals
Description
Filters the ordered point cloud based on connected component analysis algorithms. It checks the spatial distance between points, considering points close enough as "connected" and clustering them into a block. Then, based on the physical area of the cluster and the number of points, it retains the main object areas and removes fragmented, isolated noise blocks.
Overview
Checks the connectivity between points and filters out small isolated noise blocks based on area/point count thresholds, suitable for removing flying pixels and retaining main objects.
Scenarios
-
Remove Flying Pixel Noise: Depth cameras often produce isolated "flying pixels" at object edges. This operator can effectively remove these unconnected small noise points.
-
Small Region Removal: Removes tiny objects or distractions in the scene that are too small in area to meet detection requirements.
-
Retain Main Body: Quickly extracts major connected regions in the scene with a large number of points and a large area.
Inputs and Outputs
Inputs |
Organized point cloud: Organized point cloud data that maintains the 2D structure of camera imaging. |
Outputs |
Filtered point cloud: Point cloud data retained after connected component filtering. |
Parameters
Connectivity Distance Threshold
Description |
Defines the maximum spatial distance for two points to be considered "connected/neighbors". |
Tuning Instructions |
|
Parameter Range |
[0, 800], Default value: 5 |
Parameter Range |
Values/Range: [0.0, 800.0] Default: 5.0 |
Cluster Area Threshold
Description |
Defines the minimum physical area required for a connected component to be retained. |
Tuning Instructions |
If the coverage area of a cluster is less than this value, it is considered noise and removed.
|
Parameter Range |
[1, 1000], Default value: 300 |
Parameter Range |
Values/Range: [1, 1000] Default: 300 |
Minimum Cluster Points
Description |
Defines the minimum number of points required for a connected component to be retained. |
Tuning Instructions |
If a cluster contains fewer points than this value, it is removed. Usually set to 10-50 to remove a very small amount of isolated noise points. |
Parameter Range |
[1, 1000], Default value: 10 |
Parameter Range |
Values/Range: [1, 1000] Default: 10 |
Maximum Cluster Points
Description |
Number of points to judge a valid connected component. |
Tuning Instructions |
If the number of points in a connected component is greater than this value, the area is considered a valid large object sufficiently large and reliable, and the point cloud in that area is directly retained. |
Parameter Range |
[1, 1000], Default value: 300 |
Parameter Range |
Values/Range: [1, 1000] Default: 300 |
Enable Node
Description |
Controls whether this operator performs the filtering operation. |
Tuning Instructions |
|
Parameter Range |
Default: True |