GigE/GenICam Camera

Description

Probes by IP and uses GenTL/GenICam through CTI, falling back to raw GigE.

Overview

Connects to a GigE/GenICam camera and captures one frame.

Scenarios

Acquire images or point clouds from GigE/GenICam cameras.

Inputs and Outputs

Inputs

Enable Node: Capture is skipped when False.

Outputs

Image: 2D color image.

Point Cloud: 3D cloud; empty for 2D-only devices.

Camera parameters: Intrinsics, distortion, color-camera, and passive-stereo parameters.

Parameters

Camera IP/Serial Number

Description

Identifies the camera to connect. Raw GigE uses an IPv4 address; a GenTL/CTI backend can also match a device ID or serial-number keyword. Treat the real identifier as deployment configuration and do not disclose it in public documentation or logs.

Tuning Instructions

Enter the actual camera address; if connection fails, verify the camera address and host subnet.

Parameter Range

Default: 192.168.1.100

Capture Timeout (s)

Description

Maximum time to wait for one capture to return an image or point cloud. Increase it for network latency or long 3D exposure; too small rejects valid slow frames, while too large delays failure reporting.

Tuning Instructions

Increase it when valid frames do not return before timeout; decrease it to report an unresponsive camera sooner.

Parameter Range

[0.5, 60.0], Default: 10.0, Unit: s

Parameter Range

Values/Range: [0.5, 60.0]

Default: 10.0

Unit: s

GVSP Packet Size

Description

Sets the raw-GigE GVSP packet size. Standard-MTU networks normally use 1500 bytes; increase it only when camera, switches, and NIC all support jumbo frames, otherwise fragmentation or packet loss may occur. A GenTL/CTI driver may manage this independently.

Tuning Instructions

Use 1500 on a standard-MTU network; increase it only when the camera, switches, and NIC all use jumbo frames.

Parameter Range

[576, 9000], Default: 1500, Unit: byte

Parameter Range

Values/Range: [576, 9000]

Default: 1500