Calibration Board Detection

Description

This operator is used to detect the calibration board in the image and calculate the actual size and spatial pose of the currently detected calibration board.

Overview

Detects the calibration board in the input image and calculates its actual size and pose.

Scenarios

Generally used in camera calibration and hand-eye calibration scenarios to calculate the relative position between the camera and the robot.

Inputs and Outputs

Inputs

Image: RGB image used to detect the calibration board.

Camera coordinate system point cloud: Point cloud data collected in the camera coordinate system, used for calibration board pose calculation.

Outputs

Size: The actual size of the detected calibration board.

Pose Matrix: The pose matrix of the calibration board, including rotation and translation information, used for subsequent calibration and coordinate transformation.

Parameters

Number of Calibration Circles

Description

The number of rows and columns of the circular pattern on the calibration board.

Tuning Instructions

For example, [4,5] indicates 4 rows and 5 columns of circles.

Parameter Range

Default: [4, 5]

Calibration Board Width

Description

The actual distance between the centers of the circles on the calibration board.

Parameter Range

[0,1000], Default value: 35, Unit: mm

Parameter Range

Values/Range: [0, 1000]

Default: 35

Calibration Board Symmetry

Description

Specifies whether the calibration board pattern is symmetric.

Tuning Instructions

Asymmetric calibration boards usually have directionality, resulting in more accurate calibration.

Parameter Range

Default: False

Minimum Circle Area

Description

Circles smaller than this area will be ignored. Please set this value according to actual scenario requirements.

Parameter Range

[0,400000], Default value: 1000

Parameter Range

Values/Range: [0.0, 400000.0]

Default: 1000

Maximum Circle Area

Description

Circles larger than this area will be ignored. Please set this value according to actual scenario requirements.

Parameter Range

[0,10000000], Default value: 1000000

Parameter Range

Values/Range: [0.0, 10000000.0]

Default: 1000000.0