Calibration Board Detection
Description
This operator is used to detect the calibration board in the image and calculate the actual size and spatial pose of the currently detected calibration board.
Scenarios
Generally used in camera calibration and hand-eye calibration scenarios to calculate the relative position between the camera and the robot.
Inputs and Outputs
Inputs |
Image: RGB image used to detect the calibration board. Camera coordinate system point cloud: Point cloud data collected in the camera coordinate system, used for calibration board pose calculation. |
Outputs |
Size: The actual size of the detected calibration board. Pose Matrix: The pose matrix of the calibration board, including rotation and translation information, used for subsequent calibration and coordinate transformation. |
Parameters
Number of Calibration Circles
Description |
The number of rows and columns of the circular pattern on the calibration board. |
Tuning Instructions |
For example, [4,5] indicates 4 rows and 5 columns of circles. |
Parameter Range |
Default: [4, 5] |
Calibration Board Width
Description |
The actual distance between the centers of the circles on the calibration board. |
Parameter Range |
[0,1000], Default value: 35, Unit: mm |
Parameter Range |
Values/Range: [0, 1000] Default: 35 |
Calibration Board Symmetry
Description |
Specifies whether the calibration board pattern is symmetric. |
Tuning Instructions |
Asymmetric calibration boards usually have directionality, resulting in more accurate calibration. |
Parameter Range |
Default: False |