EpicPro Input (Single Dataset)

Description

This operator is the main entry node for the interaction between ATOM and Epic Pro, responsible for receiving data from Epic Pro. The main difference from the "EpicPro Input" operator is that this operator processes and outputs only one set of data per execution, i.e., it is for single-camera scenarios.

Overview

Receives or reads one Epic Pro data group.

Scenarios

  • Single-camera scenarios.

  • Online run: As the starting point of the algorithm flow, it receives data from Epic Pro in real-time.

  • Offline debugging and testing: Loads locally saved .epicraw files or file sequences for testing and optimizing the algorithm flow without connecting to actual hardware.

Inputs and Outputs

Inputs

Color Image: Color image

Point Cloud: Point Cloud

3D ROI: 3D ROI

Hand-eye calibration matrix (rotation vector): Hand-eye calibration matrix (rotation vector)

Camera parameters: Camera intrinsics, distortion, color-camera, and passive-stereo parameters.

Outputs

Image: List of images obtained from input or files.

Point Cloud (camera coordinate system): List of raw Point Clouds obtained from input or files.

3D ROI: 3D ROI list.

Hand-eye calibration matrix (rotation vector): Hand-eye calibration matrix.

Camera parameters: Camera intrinsics, distortion, color-camera, and passive-stereo parameters.

Parameters

Data reading method

Description

Selects the data source: EpicPro Input receives live Epic Pro data; Read local file reads a specified file; Read local folder loops through files in order.

Tuning Instructions

Choose EpicPro Input for incoming data, Read local file to test one file, or Read local folder to iterate through a directory.

Parameter Range

Options: EpicPro Input, Read local folder, Read local file, Default: EpicPro Input

Parameter Range

Values/Range:

  • EpicPro Input

  • Read local folder

  • Read local file

Default: EpicPro Input

EpicRaw File

Description

Specifies one .epicraw file, used only with input_method=inputFromFile. ROI or hand-eye calibration may come from input ports; when hand-eye calibration is absent, the source uses an identity transform.

Tuning Instructions

When the input method is Read local file, select one existing EpicRaw file.

Parameter Range

Options: .epicraw

Parameter Range

Values/Range:

  • .epicraw

EpicRaw Folder

Description

Specifies the local .epicraw directory used only with input_method=inputFromDirectory. Files are read in directory enumeration order and looped; adjacent runSpace.json may provide 3DROI and either cam2Base or cam2baseMatrix.

Tuning Instructions

When the input method is Read local folder, select a directory; add runSpace.json there when ROI or hand-eye data should come from the directory.

Run mode

Description

Selects the port and data-layout mode and must match the Epic Pro sender. Normal mode uses normal image, point-cloud, and camera-parameter ports; Passive stereo uses passive-stereo image and parameter ports and removes the point-cloud port. A mismatch raises an error.

Tuning Instructions

Choose Passive stereo for passive-stereo data or Normal mode for standard image and point-cloud data, matching the Epic Pro sender.

Parameter Range

Options: Passive stereo, Normal mode, Default: Normal mode

Parameter Range

Values/Range:

  • Passive stereo

  • Normal mode

Default: Normal mode